Call +49 (0)7250 33 13 400

EXCELLENT TOOLS & SERVICES FOR DNA, RNA, PROTEIN OR CELL RESEARCH

GeBaRunner Electrophoresis System for GeBaGels


  • Product from Gene Bio-Application Ltd (GeBA)

  • Universal horizontal electrophoresis system- for protein, DNA, RNA

  • Read-to-use gels, plug-and-run system, easy loading, no skills required

  • Saved time – no gel preparation, 60 min electrophoresis, full-proof well access

  • Saved costs – 5X less apparatus costs, 4X less running buffer required each time

  • No buffer leakage, no smiling gels, no handling of hazardous PAA powder

  • Gel-to-gel consistent results, sharp bands, accurate sizing

  • Watch the video to see how it works

geba

Request a Sample.

Description

The GeBAGels combined with the GeBARunner Electrophoresis Unit is a revolutionary pre-cast polyacrylamide mini-gel system for horizontal protein electrophoresis or DNA/RNA electrophoresis in polyacrylamide gels. The GeBAGel & GeBARunner electrophoresis system are compatible with robotic loading and can be used to automate the process.

GeBaRunner is a horizontal electrophoresis unit designed to be used in combination with GeBaGels to facilitate the simplicity and convenience of the the horizontal PAAG electrophoresis process.

GeBARunner Electrophoresis Unit provides the advantage of easier use, faster process and much smaller running buffer volumes consumption compared to conventional vertical electrophoresis systems.

Due to the horizontal operation the GeBARunner eliminates the buffer spills problems often occurring in the vertical systems top buffer chamber. It contributes to the generation of greater resolution as well as sharper protein bands. During the electrophoresis with the GeBARunner the heating of the gel problem is eliminated by ensuring equal heat distribution over the entire gel surface what allows to generate the smile-free gels.

For increased safety of the system, the GeBARunner includes a built-in proximity sensor, located in the protective safety cover, which detects the removal of the cover and shuts down the electrical power automatically.

The GeBARunner requires no adaptor for use and can be easily plugged-in to any power supply unit. Most of the power supply units can power multiple GeBARunners simultaneously.

GeBAGels are for decade the unique bestselling gels for daily lab use. GeBAGels are ready-to-use polyacrylamide gels for convenient horizontal protein or DNA electrophoresis applications. Instead of spending hours for preparation of hazardous polyacrylamide gels and struggling against leakage of vertical gel loading systems, the user now has a ready-to-use GeBAgel which needs just to be immersed into the buffer and loaded with samples. GeBaGels contain no SDS what makes them ideal for protein analysis under both native and denatured electrophoresis conditions. Each gel is available as precast ready-to-use gel with a defined well number accommodating certain sample volumes.

 

GeBaRunner

Applications

  • Protein electrophoresis
  • DNA Electrophoresis
  • RNA Electrophoresis

Advantages of GeBA horizontal electrophoresis system over the conventional vertical PAAG electrophoresis:

  • Universal horizontal electrophoresis system- for protein, DNA, RNA
  • Read-to-use gels, plug-and-run system, easy loading, no skills required
  • Saved time – no gel preparation, 60 min electrophoresis, full-proof well access
  • Saved costs – 5X less apparatus costs, 4X less running buffer required each time
  • No buffer leakage, no smiling gels, no handling of hazardous PAA powder
  • Gel-to-gel consistent results, sharp bands, accurate sizing
  • Watch the video to see how it works
bts provides Tris-glycine resolving GeBaGels and Tris-glycine gradient gels both for protein and nucleic acids electrophoresis, as well as the GeBaRunner electrophoresis unit.

Variety of Tris-Glycine GeBaGels available from bts (a guide of product catalogue numbers)

Number of wells: 1 + 1 wells 2 + 1 wells 10 wells 15 wells
Loading volume/well: 250 µl + 10 µl 100 µl/10 µl/100 µl 35 µl each 25 µl each
Homogeneous Gels        
GeBaGel 10%, Cat. No: 2G-0010-10 3G-0010-10 10G-0010-10 15G-0010-10
GeBaGel 12%, Cat. No: 2G-0012-10 3G-0012-10 10G-0012-10 15G-0012-10
GeBaGel 15%, Cat. No:     10G-0015-10 15G-0015-10
Gradient Gels        
GeBaGel 4-12%, Cat. No: 2G-0412-10 3G-0412-10 10G-0412-10 15G-0412-10
GeBaGel 4-20%, Cat. No: 2G-0420-10 3G-0420-10 10G-0420-10 15G-0420-10
GeBaGel 8-16%, Cat. No: 2G-0816-10 3G-0816-10 10G-0816-10 15G-0816-10

Approximate Protein Migration Chart in different percentage gels

Protein Migration

Specifications

Content

GeBaRunner:

  • GeBaRunner electrophoresis unit, 2 adaptors hex wrench and the Operating manual.
  • GeBaRunner Dimensions: 167 X 148 X 43.5 mm (W x H x D)

GeBaGels:

  • Supplied hermetically packed with combs-in.
  • Gel Matrix:  Acrylamide/Bis-Acrylamide
  • Buffer system: Tris-HCl
  • Stacking gel concentration: 4 %
  • Gel Thickness: 1.4 mm
  • Gel Size: 7.5 X 8 cm (W x H)
  • Gel shelf life: 12 months when stored at +4oC.

The recommended Running Buffers for GeBaGel system:

  • Denatured running buffer: 25mM Tris, 192mM Glycine ,0.1% SDS
  • Native running buffer: 25mM Tris, 192mM Glycine

Watch the video to see how the whole system works

Approximate protein Migration Chart in different concentration gels

Protein Migration

Supporting Data

References

Resources

You may also be interested in the following product(s)